Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
d84 Do not use - - - - -
d85 Do not use - - - - -
d86
Acc/Dec Output Fre-
quency Filter
0.000 to 5.000 s
0
Availa-
ble
s
page
5-39
d88 Do not use - - - - -
d89
PM Motor High-effi-
ciency Control Selec-
tion
0: Disable
1: Enable
1 - -
page
6-22
d90
Magnetic Flux Level
during Deceleration
100 to 300 %
120
Availa-
ble
%
page
7-121
d91 Do not use - - - - -
d92 Do not use - - - - -
d93 Do not use - - - - -
d94 Do not use - - - - -
d95 Do not use - - - - -
d96 Do not use - - - - -
d97 Do not use - - - - -
d98 Do not use - - - - -
d99 Extension Function 1
Bit 3: Jogging Enable via com-
munications
Do not use other bits
8
Availa-
ble
-
page
5-60
d190 Do not use - - - - -
d192 Do not use - - - - -
d198 Do not use - - - - -
d201
Position Control Feed
Forward Gain
0.00: Disable feed-forward
0.01 to 1.50
0.00
Availa-
ble
-
page
6-38
page
6-49
d202
Position Control Feed
Forward Filter
0.000 to 5.000 s
0.500
Availa-
ble
s
page
6-38
page
6-49
d203 Position Loop Gain 1
0.1 to 300.0
1.0
Availa-
ble
-
page
6-38
page
6-49
4 Parameter List
4-152
M1 Series Standard Type User's Manual (I669)