Parameter
No.
Function name Monitor or Data Range
Default
data
Setting
during
RUN
Unit Page
d41
Special Control Selec-
tion
0: Disable (Normal control)
1: Enable (Peripheral speed
constant control)
2: Do not use
3: Do not use
4: Do not use
0 - -
page
6-78
d51 Do not use - - - - -
d52 Do not use - - - - -
d55 Do not use - - - - -
d67
Motor Starting Mode
Auto Search in Speed
Sensor Vector Control
0: Disable
1: Enable (Only at restart after
momentary power failure)
2: Enable (At normal start and
restart after momentary power
failure)
1 - -
page
7-49
d68 Do not use - - - - -
d70
Speed Control Slip
Frequency Limit
0.00 to 100.00 %
100
Availa-
ble
%
page
6-14
d71 Do not use - - - - -
d72 Do not use - - - - -
d73 Do not use - - - - -
d74 Do not use - - - - -
d75 Do not use - - - - -
d76 Do not use - - - - -
d77 Do not use - - - - -
d78 Do not use - - - - -
d79 Do not use - - - - -
d80
1st PM Motor Magnet-
ic Pole Position Pull-in
Frequency
0.1 to 10.0Hz
1
Availa-
ble
Hz
page
6-65
d81 Do not use - - - - -
d82
Magnetic Flux Weak-
ening Control Function
Selection
0: Disable
1: Enable
1
Availa-
ble
-
page
6-16
d83
Magnetic Flux Weak-
ening Lower Limit
10 to 70%
40
Availa-
ble
%
page
6-16
4 Parameter List
4-151
M1 Series Standard Type User's Manual (I669)
4-2 List of Parameters by Group
4