EasyManuals Logo

Omron R88D-KN ML2 Sries User Manual

Omron R88D-KN ML2 Sries
484 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #346 background imageLoading...
Page #346 background image
8-45
8-6 Extended Parameters
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
8
Parameters Details
Select either to let the servo off or to stop the alarm when a main power alarm occurs.
Explanation of Set Values
Set main power supply alarm detection time.
The main power supply OFF detection is disabled if this is set to 2000.
Pn508
Undervoltage Alarm Selection
Setting
range
0 to 1 Unit
Default
setting
1
Data
attribute
B
All
Set value
Explanation
0
Servo is turned OFF based on the setting of the Stop Selection with Main Power Supply OFF
(Pn507) and turn it back to Servo ON state by turning ON the main power supply.
1
The Main power supply undervoltage (Alarm No.13.1) occurs. Stops the operation by the
alarm.
Pn509
Momentary Hold Time
Setting
range
70 to 2000 Unit 1 ms
Default
setting
70
Data
attribute
C
All

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-KN ML2 Sries and is the answer not in the manual?

Omron R88D-KN ML2 Sries Specifications

General IconGeneral
BrandOmron
ModelR88D-KN ML2 Sries
CategoryServo Drives
LanguageEnglish

Related product manuals