11-39
11-5 Periodic Maintenance
OMNUC G5-Series AC Servo Drives Users Manual (Built-in MECHATROLINK-II communications type)
11
Error and Maintenance
Battery Mounting Method
1. Prepare the replacement battery (R88A-BAT01G).
2. Remove the battery box cover.
3. Put the battery into the battery box.
4. Close the cover to the battery box.
Raise the tabs and remove the cover.
Plug in the connector.Insert the battery.
Close the battery box cover
by making sure the connector
wires are not pinched.