5-16
5-7 Selecting the Reverse Rotation-prohibit
This parameter is used to specify whether to enable or disable the reverse rotation com-
mand sent to the Inverter from the control circuit terminals or Digital Operator.
The parameter should be set to “not accept” when the Inverter is applied to systems that
prohibit the reverse rotation of the Inverter.
H Selecting the Reverse Rotation-prohibit (n05)
n05
Reverse Rotation-prohibit Selection Changes during
operation
No
Setting
range
0, 1 Unit of
setting
1 Default setting 0
Set Values
Value Description
0 Accept
1 Not accept