6-21
When the RUN command for forward or reverse rotation is input, the Inverter will start operating at the
lower limit regardless of whether the UP/DOWN command is input or not.
When the UP/DOWN function and inching frequency command are both assigned to multi-function
inputs, an inching frequency command input will have the highest priority.
If n62 for UP/DOWN command frequency memory is set to 1, the output frequency held by the UP/
DOWN function for 5 s or more will be stored in the memory. The output frequency will be held by the
UP/DOWN function when both UP and DOWN commands are ON or OFF together.
6-7-8 Error History (n78)
The 3G3JV stores information on the latest error.
The information on the latest error recorded is displayed by pressing the Enter Key after n78 for error
history is displayed.
The details of the information are the same as that obtained from the multi-function monitor U09.
n78
Error History Changes during
operation
---
Setting
range
--- Unit of
setting
--- Default setting ---
Note The information is read only.
Display Example
D Fault display
Fault code
D No error stored
uU 1
To clear the error history, set n01 for parameter write-prohibit selection/parameter initialization to 6.
Advanced Operation Chapter 6