3-10
3-2 Parameter Copy and Verify Function
The 3G3IV-PJVOP140 and 3G3IV-PJVOP146 Digital Operators include EEPROM
memory. All the parameters for the Inverter, the Inverter capacity, and the software ver-
sion are saved in this memory. If the memory is used, the parameter settings for the
Inverter can be copied to other Inverters.
Note: Copying can be performed between Inverters with the same power supply speci-
fications. Some parameters, however, may not be copied.
3-2-1 Parameters for the Parameter Copy and Verify Function
The following table shows the parameters used when reading, copying (i.e., writing), and verifying pa-
rameters.
Parameter
No.
Register
No.
Name Description Setting
range
Setting
unit
Default
setting
Writing
during
operation
n76 014C Paramet
er Copy
and
Verify
Function
Selects the function for
copying parameters.
Rdy: Ready to accept the
next command.
Red: Read the Inverter
parameters.
Cpy: Copy the parameters
to the Inverter.
VFy: Verify the Inverter
parameters.
Va: Verify the Inverter
capacity display.
Sno: Verify the software
number.
rdy to
Sno
--- rdy
Preparing for Operation and Monitoring Chapter 3