2-11
H Main Circuit Terminals
Symbol Name Description
R/L1
Power supply input
3G3JV-A2j: 3-phase 200 to 230 V AC
3G3JV ABj Si l h 200 t 240 V AC
S/L2
3G3JV-ABj: Single-phase 200 to 240 V AC
-
-
T/L3
-
-
Note Connect single-phase input to terminals R/L1 and S/L2.
U/T1
Motor output terminals 3-phase power supply output for driving motors.
V/T2
3G3JV-A2j: 3-phase 200 to 230 V AC
3G3JV-ABj: 3-phase 200 to 240 V AC
W/T3
-
:
-p
ase
o
3G3JV-A4j: 3-phase 380 to 460 V AC
+1
Connection terminals +1
and +2:
Connect the DC reactor for suppressing harmonics to terminals +1
and +2.
+2
reactor connect
on
terminals
–
When driving the Inverter with DC power, input the DC power to
terminals +1 and –.
(Terminal +1 is a positive terminal )
–
–
DC power supply input
terminals
.
Ground terminal Be sure to ground the terminal under the following conditions.
3G3JV-A2j: Ground at a resistance of 100 Ω or less.
3G3JV-ABj: Ground at a resistance of 100 Ω or less.
3G3JV-A4j: Ground at a resistance of 10 Ω or less, and connect
to the power supply’s neutral phase to conform to EC Directives.
Note Be sure to connect the ground terminal directly to the
motor frame ground.
Note The maximum output voltage corresponds to the power supply input voltage of the Inverter.
H Control Circuit Terminals
Symbol Name Function Signal level
Input
S1 Forward/Stop Forward at ON. Stops at
OFF.
Photocoupler
8 mA at 24 V DC
S2 Multi-function input 1
(S2)
Set by parameter n36
(Reverse/Stop)
Note NPN is the default setting
for these terminals. Wire
S3 Multi-function input 2
(S3)
Set by parameter n37
(Fault reset)
them by providing a
common ground. No
S4 Multi-function input 3
(S4)
Set by parameter n38
(External fault: Normally
open)
required. To provide an
external power supply and
wire the terminals through
S5 Multi-function input 4
(S5)
Set by parameter n39
(Multi-step reference 1)
a common positive line,
however, set the SW7 to
SC Sequence input com-
mon
Common for S1 through
S5
an
ma
e sure
a
the power supply is at
24 V DC ±10%.
FS Frequency reference
power supply
DC power supply for fre-
quency reference use
20 mA at 12 V DC
FR Frequency reference in-
put
Input terminal for fre-
quency reference use
0 to 10 V DC
(input impedance: 20 kΩ)
FC Frequency reference
common
Common for frequency
reference use
Design Chapter 2