TX1 also allows “shelving” of a DCO or AMA for source drives. When enabled
for a given source drive, the Shelve DCO/AMA feature will, after the
duplication job is started, disable the DCO/AMA, complete the acquisition of the
entire source drive, and then attempt to reapply the original DCO/AMA setting
back to the source drive. This provides a convenient way to ensure that all
source evidence is acquired and that the drive is returned to its original state at
the end of the duplication job. See the source selection screenshot above for an
example of a selected source drive with a DCO. Note that this Shelve DCO/
AMA feature is only available for SATA drives that support DCO/AMA. See
“Drive capacity and transfer rate measurement conventions” on page 7 for more
details regarding DCO/AMAs and how TX1 supports them.
Note: You cannot browse a source drive if the Shelve DCO/AMA feature is
being used on an active job with that drive.
5. To change or add the destination drive(s) tap the 3 or Destination(s) heading.
From the destination list modal that is displayed, select one or more drives from
the list.