EasyManuals Logo

Oracle ZFS Storage Appliance Service Manual

Oracle ZFS Storage Appliance
364 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
Viewing the Remaining SSD Endurance (CLI)
CLI Property BUI Property
serial Serial
size Size
speed Speed
type (combined with use)
use Type
When viewing a disk that is active as a hot spare, the detach command is also available.
Viewing the Remaining SSD Endurance (CLI)
Use the following procedure to view the remaining SSD endurance.
To list the properties of a disk, use the following CLI commands:
hostname maintenance hardware
hostname:maintenance hardware> select chassis-001
hostname:maintenance hardware chassis-001> select disk
hostname:maintenance hardware chassis-001> select disk-015
hostname:maintenance hardware chassis-001 disk-015> list
Properties:
label = HDD 15
present = true
faulted = false
manufacturer = SANDISK
model = LB806M---SUN800G
serial = 40042896
revision = S30E
size = 745G
type = data
use = data
rpm = --
device = c0t5001E82002630190d0
pathcount = 2
interface = SAS
endurance = 100%
endurance_updated = 2014-3-3 22:04:14
locate = false
offline = false
As shown above, disk-015 is at 100% which indicate a new SSD. The remaining endurance
estimate decreases as the disk is used.
28 Oracle ZFS Storage Appliance Customer Service Manual • July 2016

Table of Contents

Other manuals for Oracle ZFS Storage Appliance

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Oracle ZFS Storage Appliance and is the answer not in the manual?

Oracle ZFS Storage Appliance Specifications

General IconGeneral
Connectivity10GbE, 40GbE, InfiniBand, Fibre Channel
ProtocolsNFS, SMB, iSCSI, Fibre Channel, HTTP
Operating SystemOracle Solaris
Data Protectionsnapshots, clones, remote replication
Data ReductionInline compression, deduplication
High AvailabilityRedundant hardware components (controllers, power supplies, fans). Automatic failover between controllers. Hot-swappable drives and components. Cluster configurations for increased availability and scalability.
Management InterfaceWeb-based GUI, CLI, REST API
Storage TypeHybrid (SSD + HDD), All-Flash
Storage CapacityUp to several petabytes
EncryptionAES-256 encryption at rest

Related product manuals