INF-40
PB ADJUST (DVCPRO 50M ADJUST, DVCPRO 25M ADJUST sub-screen)
Item Set value
No.
SUPER
DISP.
No.
SUPER
DISP.
Setting contents and
outline function explanation
BACK
-UP
Remarks
P01
Q01
PHS L1
-128
|
-20
|
127
-128
|
-20
|
127
Adjustment of the L1 head playback phase
Yes Use for electrical adjustment
P02
Q02
PHS L2
-128
|
-20
|
127
-128
|
-20
|
127
Adjustment of the L2 head playback phase
Yes Use for electrical adjustment
P03
Q03
MAG L1
-128
|
20
|
127
-128
|
20
|
127
Adjustment of the L1 head playback amplitude
Yes Use for electrical adjustment
P04
Q04
MAG L2
-128
|
20
|
127
-128
|
20
|
127
Adjustment of the L2 head playback amplitude
Yes Use for electrical adjustment
P05
Q05
PHS R1
-128
|
-20
|
127
-128
|
-20
|
127
Adjustment of the R1 head playback phase
Yes Use for electrical adjustment
P06
Q06
PHS R2
-128
|
-20
|
127
-128
|
-20
|
127
Adjustment of the R2 head playback phase
Yes Use for electrical adjustment
P07
Q07
MAG R1
-128
|
20
|
127
-128
|
20
|
127
Adjustment of the R1 head playback amplitude
Yes Use for electrical adjustment
P08
Q08
MAG R2
-128
|
20
|
127
-128
|
20
|
127
Adjustment of the R2 head playback amplitude
Yes Use for electrical adjustment
P09
Q09
ENV L1
0
|
255
0
|
255
Yes
Factory use only
P10
Q10
ENV L2
0
|
255
0
|
255
Yes
Factory use only
P11
Q11
ENV R1
0
|
255
0
|
255
Yes
Factory use only
P12
Q12
ENV R2
0
|
255
0
|
255
Playback signal envelope level read-out value averaged for each
track of each head
ENV L1: L1 head
ENV L2: L2 head
Averaging is performed at 8 points in the track, and the newest track
value for which averaging has been completed at the time when
read-out is started will be read out.
Read-out is possible only at the time of PLAY and REC.
Yes
Factory use only
P13
Q13
AGC SPD
0
|
3
0
|
3
Setting of the AGC response speed
Yes
Factory use only
Do not change any setting
P14
Q14
AEQ SPD 0
1
2
3
0
1
2
3
The control response speed for the adaptive equalization filter is set
in four levels.
The sensitivity is highest with 0 and lowest with 3.
Yes
Factory use only
Do not change any setting
P15
Q15
HLD SEN 0
1
2
3
0
1
2
3
The detection sensitivity for detection of changes in the relative
speed is set in four levels.
The sensitivity is highest with 0 and lowest with 3.
Yes
Factory use only
Do not change any setting

Table of Contents