11.2 Operation at Over Limit Input
Operation at over limit input
Operations depend on the status of over limit input (+) and over limit input (-) as follows.
Condition Direction Limit status Operation
When pulser input
operation is executed
Forward
Over limit input (+): ON
Not executable, Error
occurs.
Over limit input (-): ON Executable
Reverse
Over limit input (+): ON
Executable
(Note 1)
Over limit input (-): ON
Not executable, Error
occurs.
During pulser input
operation
Forward Over limit input (+): ON Stop, Error occurs.
Reverse Over limit input (-): ON Stop, Error occurs.
(Note 1) The Pulse/Sign output mode can be executed. An over limit error occurs when the CW or CCW output
mode has been set.
Input valid logic of over limit input
When the over limit switches (+) (-) are not connected to the pulse output unit, change the
over limit input valid logic of the Pulse_4Axes parameter to "NO contact". The default is "NC
contact", and an over limit error occurs.
Precautions on over limit switch
An over limit input valid for JOG operation, home return and pulser operation is the one
logically found in the direction of the movement. Even if an over limit switch (-) is input for a
movement in (+) direction or an over limit switch (+) is input for a movement in (-) direction,
the operation will not stop.
Make sure that an over limit switch (+) is set in the direction of the elapsed value increment
and an over limit switch (-) in the direction of the elapsed value decrement.
When a switch is not set in the correct direction, the followings might be a cause. Check your
settings and correct them.
1) An over limit switch, (+) or (-), is not set in a correct direction.
2) CW / CCW output method is set reverse for the connection of the pulse output unit and
the motor driver.
3) A sign input logic is set reverse for the connection of the pulse output unit and the motor
driver.
4) Among the Pulse_4Axes parameters, the rotation direction (forward or reverse) of pulse
output is reversely specified.