12.1.2 Forced Stop
This section describes a program example for making a forced stop using the PG_Stop function
block while the PG_MoveRelative function block is being executed.
When the PG_Stop function block is executed with the StopMethod input parameter set to
TRUE while the motor is in operation, a forced stop is performed
This operation is common to E-point control, P-point control, home return, JOG operation,
JOG positioning operation and pulser input operation.
For each function block that is being operated, CommandAborted is set to TRUE and the
function block is interrupted.
Pulse output diagram: Forced stop
Parameter Settings
PG_Stop parameter
Parameter Set value Setting range
StopMethod TRUE TRUE: Forced stop
FALSE: Deceleration stop
12.1 Sample Program
12-4 WUME-GM1PG-01