Solution 3
Check to make sure the wiring between the pulse output unit and the driver has been
correctly connected.
Check to make sure the 24 V DC voltage is supplied to the external power supply terminals
(terminal numbers A20 and B20).
Solution 4
Check to make sure the settings for the pulse output method (CW / CCW method or Pulse /
Sign method) are appropriate for the driver.
15.3.4 If the Motor Does Not Turn (if the LED for pulse output A or B is not lit)
Solution
Review the program.
Check the following items.
Check the input logic of the over limit switch. In this case, the error LED is lit.
15.3.5 Rotation/Movement Direction is Reversed
Situation
Solution 1
Make sure the wiring between the pulse output unit and the driver has been correctly
connected.
Make sure the CW / CCW output or the Pulse / Sign output has been connected to the
pertinent input on the driver side.
Solution 2
Make sure the command position of the function block is correctly specified.
Specify the Pulse / Sign output and CW / CCW output using the GM Programmer.
Solution 3
If the settings for the position command data have been designed with the plus (+) and minus
(-) directions reversed, change the direction of rotation using the parameter.
15.3 What to Do If an Error Occurs