3.7 Connection of Deviation Counter Clear Output Signal
This is an example showing the connection of the counter clear input to the servo amplifier.
An external power supply (+5 V DC to +24 V DC) must be provided for the connection.
Always use twisted-pair cables for wiring.
The current which can be conducted as the deviation counter clear output signal is 10 mA max.
If this is exceeded, a resistance should be added.