6.2 Over Limit Input
■
Operation at over limit input
Operations depend on the status of over limit input (+) and over limit input (-) as follows.
Condition Direction Limit status Operation
When E-point control is
started
Forward
Over limit input (+): ON
Not executable, Error
occurs.
Over limit input (-): ON
Not executable, Error
occurs.
Reverse
Over limit input (+): ON
Not executable, Error
occurs.
Over limit input (-): ON
Not executable, Error
occurs.
While E-point control is
being performed
Forward
Over limit input (+): ON Stop, Error occurs.
Over limit input (-): ON Stop, Error occurs.
Reverse
Over limit input (-): ON Stop, Error occurs.
Over limit input (-): ON Stop, Error occurs.
■
Input valid logic of over limit input
● When the over limit switches (+) (-) are not connected to the pulse output unit, change the
input valid logic of the over limit switch to "NO contact". The default is "NC contact", and an
over limit error occurs.
6.2 Over Limit Input
WUME-GM1PG-01 6-7