Mains Motor Power
Use Table 41 to determine the appropriate mains filter for your
drive/controller.
Filter Continuous Current
(Amps)
AR-04CE AR-08CE AR-13CE
6EP1 (160937-5)
1
5 at 240 VAC
10EP1 (160937-7)
1, 3
8 at 240 VAC
× ×
x
FN2070-10/06
2
10 at 240 VAC
× ×
x
FN2070-12/06 12 at 240 VAC
× ×
x
FN2070-16/06
2, 3
16 at 240 VAC
× ×
x
16FCD10
1
16 at 240 VAC
25FCD10
1
25 at 240 VAC
Product with applicable mains filter denoted by “×
1. Corcom (a division of Tyco Electronics)
2. Schaffner
3. Available from Parker: 10 Amp filter—part number 47-016140-01
16 Amp filter—part number 47-017900-01
Table 41 Mains Motor Power Filter Selection
Follow these requirements for mains power connections:
Install transient suppressors.
Single Phase Input
You must install varistors or other voltage surge-limiting devices in order
to meet the requirements of EN61000-4-5. Place a Littelfuse
V275LA2ØC, or equivalent varistor, from line to line and from lines to
earth before the mains filter, as shown in the EMC Installation drawings.
Note: Intersil, General Electric, and Littelfuse manufacture equivalent
varistors.
Use an EMC-ready motor or a motor that has demonstrated acceptable
EMC performance.
Motors with shielded cabling or pipe thread style cabling options allow
the easiest integration into machines required to bear the CE mark for
EMC.
Note: Motors may bear the CE mark. This mark indicates the motor
meets the requirements of construction and safety—not EMC
compliance.
Use shielded cabling with braided and bonded headshells. Use of
Parker CE/EMC-compliant cables is recommended—they are fully
shielded and provide the required screening. Parker cabling requires no
additional cable preparation.
All motor connections must be made using a high quality braided-screen
cable. Cables using a metalized plastic bandage for an earth screen are
unsuitable and in fact provide very little screening. Care must be taken
when terminating the cable screen, the screen itself is comparatively
fragile; bending it round a tight radius can seriously affect the screening