The Aries Controller drive operates in an ambient temperature range of 0°C
(32°F) to 50°C (120°F) ambient air temperature. The drive can tolerate
atmospheric pollution degree 2. Only dry, non-conductive pollution is
acceptable. Therefore, it is recommended that the drive be mounted in a
suitable enclosure.
For drive cooling, you must install the drive so that the heat sink fins are
vertical. Figure 4 on page 12 shows the mounting orientation, as well as the
minimum top,
bottom, and side installation clearances.
Notes
Avoid installing heat-producing equipment directly below a drive.
Make sure the ambient air temperature entering the drive or rising up to
the drive is within acceptable ambient temperature limits. Under normal
use, the temperature of air leaving the drive and heat sink may be 25°C
(45°F) above ambient temperature.
After installation, verify that the ambient air temperature directly below
the top-most drive does not exceed the maximum Ambient Air
Operating Temperature shown below. In addition, make sure that
nothing obstructs the circulating airflow.
Environmental Specifications
Operating Temperature,
Ambient Air
Maximum 50°C (120°F)
Minimum 0°C (32°F)
Storage Temperature –40°C to 85°C (–40°F to 185°F)
Humidity 0 to 95%, non-condensing
Shock: 15g, 11 ms half-sine
Vibration 10 to 2000 Hz at 2g
Pollution Degree 2 (per IEC 61010)
Installation Category 2 (per IEC 61010)
Table 3 Environmental Specifications