Parker Hannifin
Chapter 3 Electrical Installation - 19 -
Factory Installed Jumpers
The Aries Controller comes with external jumpers installed in the Input Power
/ Mains connector from C1 to L1, and C2 to L2. Figure 10 shows the location
of the factory installe
d jumpers.
Figure 10 Factory-Installed Jumpers on Input Power / Mains Connector
Motor Feedback Connector
Inputs for the encoder feedback, motor thermal switch, and hall effects are
located on the 15-pin Motor Feedback connector.
Figure 11 Motor Feedback Connector, Female
Motor Feedback Connector Specification
Connector Type.......................................15-Pin High Density
D-Subminiature
(female socket)
Manufacturer........................................... KYCON or equivalent
KYCON Part Number..............................K66-E15S-NR
Motor Feedback Connector Specification—Mating
Connector
Mating connectors are not provided with the drive. Parker cables are
available with mating connectors attached.
Connector Type.......................................15-Pin High Density D-Subminiature
(male connector)
Manufacturer........................................... AMP or equivalent