EasyManua.ls Logo

Parker Aries AR-04CE - Drive Inrush Current; Table 20 Drive Motor Power Inrush Current

Parker Aries AR-04CE
129 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker Hannifin
- 30 - Aries Controller Hardware Installation Guide
Control Power Fuse Information
Each Control Power input line must be protected by the following fuse:
Fuse Rating............................................. 1 Amp
Fuse Type ...............................................Class CC (Bussmann KTK-R-1 or
equivalent UL listed fuse)
Input Voltage Range ............................... 120/240 VAC, 50/60 Hz
Input Current ...........................................0.2 Amps RMS
Control Power Functions......................... Communications
Diagnostics
Motor position feedback
Brake relay in brake mode
Drive I/O signals
Drive Inrush Current
The drive inrush current is limited by an internal thermistor that changes
value with the ambient temperature. Drive inrush current is therefore
dependent upon the temperature of the surrounding environment (T
amb
). To
determine the drive inrush current for your drive, see Table 20.
Drive Type AC Voltage Drive Inrush
at T
amb
=
25°C
Drive Inrush
at T
amb
= 50°C
120 VAC 17A 36A
AR-04CE
240 VAC 34A 73A
120 VAC 17A 36A
AR-08CE
240 VAC 34A 73A
120 VAC 17A 36A
AR-13PE
240 VAC 34A 73A
Table 20 Drive Motor Power Inrush Current

Table of Contents