Parker Hannifin
- 18 - Aries Controller Hardware Installation Guide
Input Power / Mains Connector
The Input Power / Mains connector contains terminals for external
regeneration, control power, and motor power. Do not connect power to this
connector before reading the section Power Supply o
n page 29.
The Input Po
wer / Mains connector provides terminals L1, L2, and
for
connecting motor mains power. It also serves to connect Control power
through terminals C1 and C2, and a power dissipation resistor on terminals
R+ and R–. The connector is removable.
Connector Type.......................................Removable screw terminal
Terminals ........................................7
Pitch ................... 0.200 in (5.08 mm)
Wire Range....................12-26 AWG
.......................................14-27 SWG
................................(0.12-3.30 mm
2
)
Wire Strip length .. 0.31 in (7.87 mm)
Torque....7.0 in–lbs nom. (0.79 N-m)
Figure 9 Input Power / Mains Connector
Important — Power to the Aries Controller can be supplied in two ways. See
the section Power Supply on
page 29 before proceeding with connecting the
unit to power.