Parker Hannifin
P Series User Guide 151
C. While operating at Zero search speed, the first index pulse is detected, and the motor
rotates to the index position (Home).
Methods -3, -4
Homing Methods -1, -2 uses only Stopper to return to origin. The speed profile of each sequence
is as follows. Please see the explanations below for further details.
A. The initial direction is reverse (CW). The motor operates at the switch search