EasyManua.ls Logo

Parker P Series

Parker P Series
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker Hannifin
P Series User Guide 174
Related Objects
Index
Sub
Index
Name
Variable
Format
Accessibility
PDO
Allocation
Unit
0x2304 - Program Jog Operation Speed 1 INT RW No rpm
0x2305 - Program Jog Operation Speed 2 INT RW No rpm
0x2306 -
Program Jog Operation Speed 3
INT RW No rpm
0x2307 -
Program Jog Operation Speed 4
INT RW No rpm
0x2308 - Program Jog Operation Time 1 UINT RW No ms
0x2309 -
Program Jog Operation Time 2
UINT RW No ms
0x230A
-
Program Jog Operation Time 3
UINT RW No ms
0x230B
-
Program Jog Operation Time 4
UINT RW No ms
Table 90. Program Jog Operation Related Objects
7.1.3 Alarm Record Detection
This function deletes all alarm code history Stored in the drive. The alarm history of the
newest alarm and up to 16 previous alarms is Stored in the drive.
The alarm history can be viewed at0x2702:01~16, as shown below. The newest recent
alarm is displayed at 0x2702:01.
www.comoso.com

Table of Contents

Related product manuals