Loading...
Parker Hannifin
P Series User Guide 206
SubIndex 5
Variable
Format
Setting Range
Default
Value
Unit
Accessib
ility
PDO
Allocation
Change
Property
Store
UDINT
0 to 0xFFFFFFFF
0
-
RW
No
-
No
Table 104. Restore Parameters
Reset the drive’s parameters. To prevent mistakes, using the ASCII code
corresponding to ‘load’ will reset the parameters.
0x64
0x6C
MSB
LSB
16 15
0x6F
0x61
d
l
o
a
ASCII 코드
Writing “load” at SubIndex 1 will reset all parameters.
Writing “load” at SubIndex 2 will reset only communication parameters (0x1000~)
Writing “load” at SubIndex 3 will reset only parameters (0x6000~).
Writing “load” at SubIndex 4 will reset only the drive’s specific parameters (0x2000~)
Writing “load” at SubIndex 5 will reset only Index parameters (0x3000~).
The drive needs to be restarted for the reset value to apply.
0x1018
Identity Object
SubIndex 0
Variable
Format
Setting Range
Default
Value
Unit
Accessib
ility
PDO
Allocation
Change
Property
Store
USINT
-
4
-
RO
No
-
No
SubIndex 1
Variable
Format
Setting Range
Default
Value
Unit
Accessib
ility
PDO
Allocation
Change
Property
Store
UDINT
-
0x00007595
-
RO
No
-
No
SubIndex 2
Variable
Format
Setting Range
Default
Value
Unit
Accessib
ility
PDO
Allocation
Change
Property
Store
UDINT
-
0x00010001
-
RO
No
-
No
SubIndex 3
Variable
Format
Setting Range
Default
Value
Unit
Accessib
ility
PDO
Allocation
Change
Property
Store
UDINT
-
-
-
RO
No
-
No
SubIndex 4
Variable
Format
Setting Range
Default
Value
Unit
Accessib
ility
PDO
Allocation
Change
Property
Store
UDINT
-
-
-
RO
No
-
No
Table 105. Identity Object
Shows information on the device