P Series User Guide 129
0x6065 - Following Error Window UDINT RW No UU
0x6066 - Following Error Timeout UINT RW No ms
0x6067 - Position Window UDINT RW No UU
0x6068 - Position Window Time UINT RW No ms
0x6091
- Gear Ratio - - - -
0 Number of entries USINT RO No -
1 Motor Revolutions UDINT RW No -
2 Shaft Revolutions UDINT RW No -
0x240C - Modulo Factor DINT RW No UU
0x3000 - Control Mode UINT RW No -
0x3001 - Coordinate Select UINT RW No -
0x3002 - Baud Rate Select UINT RW No -
0x3003 - Pulse Input Logic Select UINT RW No -
0x3004 - Pulse Input Filter Select UINT RW No -
0x3005 - PCLEAR Mode Select UINT RW No -
0x3006 - Encoder Output Pulse UDINT RW No Pulse
0x3007 - Encoder Output Mode UINT RW No
0x3008 - Start Index Number(0~63) UINT RW No -
0x221C -
Analog Torque
Input(Command/ Limit)
Scale
UINT RW Yes 0.1%/V
0x221D -
Analog Torque
Input(Command/ Limit)
Offset
INT RW Yes mV