Figure 15. System Installation Overview
Warning
This product has been developed for industrial environments. Due to exposed high
voltage terminals, this product must not be accessible to users while under normal
operation.
3.3 Power Supply
3.3.1 Power Circuit Electronics Specification
Type 400W 1kW 3.5kW
MCCB ABS33bM(8A) 12A 24A
Noise Filter
(NF)
RFY-4010M 4020M 4030M
DC Reactor HFN-6(6A) HFN-10(10A) HFN-30(30A)
MC GMC-9(11A) GMC-18(18A) GMC-40(35A)
Power Cable
AWG16
(1.25 SQ)
AWG14
(2.0 SQ)
AWG12
(4.0 SQ)
Pressure
Terminal
UA-F1510, SEOIL
(10mm Strip & Twist)
UA-F2010, SEOIL
(10mm Strip & Twist)
UA-F4010, SEOIL
(10mm Strip & Twist)
Recovery
Resistance
(default)
50[W]
100Ω
100[W]
40Ω
150[W]
13Ω
Table 12. Power Circuit Electronics Specification