Parker Hannifin
P Series User Guide 165
Analog Torque
Limit
(Set Value 4)
The torque is limited using the torque limit value depending on the
analog input voltage.
- Regardless of the positivity/negativity of analog input voltage, when
inputting +/-10[V], the torque is limited in the forward/reverse direction
with 300[%]torque
- The relationship between analog input voltage and torque limit is as
follows.