Parker Hannifin Manufacturing Srl user’s manual TPDM
Par. Description Range Def.
Acceleration ramp for negative speed: Negative speed
acceleration required by the motor via the speed reference is
internally limited so that to achieve an acceleration of 1000
rpm, Pr10 seconds are necessary.
65.535
[s/krpm]
M
Deceleration ramp for negative speed: Positive speed
deceleration required by the motor via the speed reference is
internally limited so that to achieve an acceleration of 1000
rpm, Pr11 seconds are necessary.
65.535
[s/krpm]
M
Deceleration ramp for limit switch and stop functions:
Deceleration required by the motor for limit switch and stop
functions is internally limited so that to achieve an
acceleration of 1000 rpm, Pr12 seconds are necessary.
65.535
[s/krpm]
M
Overspeed limit: If the absolute value of the motor speed
exceeds the value set in Pr13, b41.0 will be =1, Otherwise,
it will be = 0.
[rpm]
M
High speed limit: If b40.7=0 and if the difference of the
speed of the motor and the reference is less than Pr14 and
greater than Pr15, b41.1 will be = 1. Otherwise, it will be 0.
If b40.7 = 1 and if the motor speed is less than Pr14 and
greater than Pr15, b41.1 will be =1. Otherwise, it will be =0.
[rpm]
M
Low speed limit: If b40.7=0 and if the difference of the
speed of the motor and the reference is less than Pr14 and
greater than Pr15, b41.1 will be =1. Otherwise, it will be =0.
If b40.7=1 and if the motor speed is less than Pr14 and
greater than Pr15, b41.1 will be =1. Otherwise, it will be =0.
[rpm]
M
Integral gain of the speed regulator.
Damping of the speed regulator: If Pr16=0, Pr17 is the
proportional gain of the speed regulator.
Band width limiter: Pr18 is used to set the time constant of
a first order filter placed on the digital signal of the torque
request. The frequency of the filter cut will be: 1240/Pr18
[1=128
µsec]
M
Peak current: This is the maximum current that the
converter can supply to the motor. It is expressed as a
percentage of the peak current of the converter. In general,
it should never exceed three times the rated current of the
motor.
(see the appendix “switching frequency”)
[%Ip]
M
DC bus voltage: Displays the value of the voltage present
on the DC bus.
Torque limiter (read-only): Can be used by the operating
modes to limit the torque to the motor.
Second analogue input: Represents the value of the main
analogue input.
Alarm code: This is the code for the alarm that is present.
Code 0 represents the absence of alarms. Consult the table
of alarm codes for more details.