70
Par. Description Range Def.
Type/
Note
Pr200
N. of turn for Multiturn encoder. In the case of encoder
multiturn the parameter show the maximum turn of the
device.
[turn]
0
R
Pr201
Encoder vibration step. (see section “encoder phasing”)
Pr202
Encoder CAN address. (see section “encoder CAN”)
Pr203
(**)
Motor temperature pre-alarm. The user can fix the motor
temperature to set pre-alarm flag (b232.12).
[count]
832
R/W
Pr204
(**)
Motor temperature alarm. The user can fix the motor
temperature to rise alarm event.
[count]
550
R/W
Pr205
(**)
Motor temperature. Motor temperature estimate.
[count]
-
R
Pr206
(*)
Nominal DC BUS. When the drive is supplied in
continuous voltage, the power supply voltage value must be
written in this parameter. This configuration is enabled at
the start-up the drive.
The default status of the drive is configured to 400VAC
(=560V DC). For all other
cases, it’s necessary to set the
correct value of the voltage, and the configuration must be
executed only by the first axis connected to the PSU device.
To activate the new configuration, it’s necessary to save the
parameter and restart the PSU unit.
[V DC]
560
W
Pr208
Braking resistance. In “Ω”. [Not used]
40
R
Pr209
Power of the braking resistance. In “W”. [Not used]
120
R
Pr217
Selection (0) synchronous motor, (1) asynchronous
motor, (2) Asynchronous motor without feedback.
0:
rotative brushless motor;
1: asynchronous motor 4 poles to
vectorial control with sensor; 2:
Asynchronous motor V/F
controlled
0÷2
0
R/W
M
Pr218
Base speed async. Asynchronous motor speed in
synchronism conditions.
2
Pr29
f 60
218Pr
n
×
==
S
ω
[rpm]
0
R/W
M
Pr219
SLIP ASYNC. Asynchronous motor slip.
0÷32767
[rpm]
0
R/W
M
Pr220
MAGN CURR ASINC. Asynchronous motor magnetizing
current.
ϕ
2
cos-1 Pr33 220Pr ×=
Dove:
n
n
n
I
V
P
×
××
=
3
cos
η
ϕ
, in cui V
n
ÆPr308; I
n
ÆPr33
0÷32767
[A]
0
R/W
M
Pr283
Speed FFWD gain. To enable the gain set the value
calculated, see the par. “feed forward
speed loop”. If the
value is 0, the FFWD gain is disabled.
0÷2000
0
R/W
Pr284
Speed FFWD monitor. (see the par. “feed forward speed
loop”)
0÷100.0
-