Parameter
ID (hexa-
decimal)
Data
Type
Command
Level for
Write
Access
Item Type Parameter
Name
Description
0x0b000007 FLOAT 1 Output
signal
channel
Min Output
Voltage of
Amplifier
Settings valid when used as
output voltage for a piezo
actuator in the stage (output on
the socket for piezo stages).
Limited by Soft Voltage Low Limit
(ID 0x0c000000) and Soft Voltage
High Limit (ID 0x0c000001).
0x0b000008 FLOAT 1 Output
signal
channel
Max Output
Voltage of
Amplifier
0x0b000009
FLOAT
2
Output
signal
channel
Voltage of
Amplifier with
zero to Dac
0x0b00000a FLOAT 1 Output
signal
channel
Voltage Offset
of Amplifier
0x0b000500 INT 1 Output
signal
channel
Output
Numerical
Format
7 = raw format (used for
driver/DAC issues)
0x0b000800 INT 1 Output
signal
channel
Input Index To
Feed Back
Not relevant for E-727
0x0b000a00
FLOAT
2
Output
signal
channel
Min Output
Voltage of 2nd
Output
Settings valid when used as
control signal for an external
amplifier (output on pin 8 of the
Analog I/O socket).
Only present with E-727 models
equipped with an Analog I/O
socket (E-727.xxxA, .xxxAx).
0x0b000a01
FLOAT
2
Output
signal
channel
Max Output
Voltage of 2nd
Output
0x0b000a02 FLOAT 2 Output
signal
channel
Voltage of 2nd
Output with
zero to Dac
0x0c000000 FLOAT 1 Output
signal
channel
Soft Voltage
Low Limit
ID-chip
Limits the output voltage for a
piezo actuator in the stage
(output on the socket for piezo
stages).
0x0c000001 FLOAT 1 Output
signal
channel
Soft Voltage
High Limit
0x0d000000 CHAR 2 System Device S/N
0x0d000100 CHAR 2 System Hardware S/N
0x0d000200
CHAR
2
System
Hardware Name
0x0d000300 INT 3 System Fieldbus
Product Code
Identification of the E-727 in the
EtherCat network
0x0e000100 FLOAT 2 System Sensor Sampling
Time
[s]

Table of Contents