User Manual
E727T0005, valid for E-727
BRO, 2019-06-28
Physik Instrumente (PI) GmbH & Co. KG, Auf der Roemerstrasse 1, 76228 Karlsruhe, Germany Page 202 / 240
Phone +49 721 4846-0, Fax +49 721 4846-1019, Email info@pi.ws, www.pi.ws
Parameter
ID (hexa-
decimal)
Data
Type
Command
Level for
Write
Access
Item Type Parameter
Name
Description
0x14000001 INT 1 Axis DDL repeat
number
For details, see “Dynamic Digital
Linearization (DDL)” (p. 114).
0x14000006 FLOAT 1 Axis Time Delay Max
0x14000008 INT 1 Axis Time Delay
Change Rule
Number
0x1400000b INT 3 System Max DDL Points
0x16000000 INT 1 System Data Recorder
Table Rate
For details, see „Data Recording“
(p. 65).
Data Recorder
Channels
0x16000200 INT 3 System Data Recorder
Max Points
0x16000300 INT 1 System Data Recorder
Chan Number
table
Source
0x16000701 INT 1 Data rec.
table
DRC Record
Option
0x18000201 FLOAT 1 Digital
output
CTO Trigger
Step
Trigger settings. For details, see
„Configuring Trigger Output“ on
p. 69.
output
0x18000203 INT 1 Digital
output
CTO Trigger
Mode
0x18000205 FLOAT 1 Digital
output
CTO
Min.Threshold
0x18000206 FLOAT 1 Digital
output
CTO
Max.Threshold
0x18000207 INT 1 Digital
output
CTO Polarity
0x18000208 FLOAT 1 Digital
output
CTO Start
Threshold