- 353 -
5.18.4 mode
Description Set downstream/upstream rate adaptive mode to init (rate
automatically selected at start up only and does not change after that),
dynamic (rate automatically selected at initialization and is
continuously adapted during show time), or manual (rate changed
manually)
Syntax mode {ds | us} {init | dynamic | manual}
Parameter None
5.18.5 noise
Description Set downstream/upstream minimum impulse noise protection.
Syntax noise {ds | us} <number>
Parameter
Name Description
number Noise (tenth symbols).
Valid values: 0~8 step 0.1
Default value: -
Type: Mandatory
5.18.6 noisemargin
Description Set Downshift/Upshift Noise Margin in downstream/upstream
direction
Syntax noisemargin {ds | us} {downshift | upshift} <number>
Parameter
Name Description
number Downshift/Upshift Noise Margin (tenth
symbols).
Valid values: 0~31 step 0.1
Default value: -
Type: Mandatory