5.19 Spectrum Profile Configure Mode Commands
The commands in this section can be executed only in the Spectrum Profile execution
mode.
5.19.1 aggregate
Description Set downstream/upstream aggregate power level
Syntax aggregate {ds | us} max powerlevel <number>
Parameter
Name Description
<number> Power level (tenth dBm).
Valid values: 0~25.5 step 0.1
Default value: -
Type: Mandatory
5.19.2 bands <index> {start | stop}
Description Set RF bands
Syntax bands <index> {start | stop} <value>
Parameter
Name Description
index Bands array index.
Valid values: 0-7
Default value: -
Type: Mandatory
value Set start / stop frequency (kHz).
Valid values: 0-12000
Default value: -
Type: Mandatory
5.19.3 bands <index> mask
Description Set bands mask
Syntax bands <index> mask <value>