SD700
POWER ELECTRONICS
94
CONFIGURATION REGISTER
PARAMETERS
FACTORY SETTINGS
SETTING 1
SETTING 2
9 MAX2 RNG=+100%
MAX RANG ANAOUT2
+100%
___________________
___________________
10 FILTER 2=OFF
FILTER ANAOUTPU2
OFF
___________________
___________________
G9: Comparators S9.1: Comparator 1
1 COMP 1 SEL=00
00
___________________
___________________
2 COMP 1 TYPE=0
0
___________________
___________________
3 SP C1 ON=+100[%]
C1 ACTIVAT LEVEL
+100[%]
___________________
___________________
4 LIM 2 C1=+100[%]
C1 WINDOW LIMIT2
+100[%]
___________________
___________________
5 LIM 1 C1=+0[%]
C1 WINDOW LIMIT1
+0[%]
___________________
___________________
6 T C1 ON=0.0s
C1 ACTIVAT DELAY
0.0s
___________________
___________________
7 SP C1 OF=0[%]]
C1 DEACTIV LEVEL
+0[%]
___________________
___________________
8 T C1 OF=0.0s
C1 DEACTIV DELAY
0.0s
___________________
___________________
9 SEL FUNT C1=00
00
___________________
___________________
G9: Comparators S9.2: Comparator 2
1 COMP 2 SEL=00
00
___________________
___________________
2 COMP 2 TYPE=0
0
___________________
___________________
3 SP C2 ON=+100[%]
C2 ACTIVAT LEVEL
+100[%]
___________________
___________________
4 LIM 2 C2=+100[%]
C2 WINDOW LIMIT2
+100[%]
___________________
___________________
5 LIM 1 C2=+0[%]
C2 WINDOW LIMIT1
+0[%]
___________________
___________________
6 T C2 ON=0.0s
C2 ACTIVAT DELAY
0.0s
___________________
___________________
7 SP C2 OF=0[%]
C2 DEACTIV LEVEL
+0[%]
___________________
___________________
8 T C2 OF=0.0s
C2 DEACTIV DELAY
0.0s
___________________
___________________
9 SEL FUNT C2=00
00
___________________
___________________
G9: Comparators S9.3: Comparator 3
1 COMP 3 SEL=00
00
___________________
___________________
2 COM 3 TYPE=0
0
___________________
___________________
3 SP C3 ON=+100[%]
C3 ACTIVAT LEVEL
+100[%]
___________________
___________________
4 LIM 2 C3=+100[%]
C3 WINDOW LIMIT2
+100[%]
___________________
___________________
5 LIM 1 C3=+0[%]
C3 WINDOW LIMIT1
+0[%]
___________________
___________________
6 T C3 ON=0.0s
C3 ACTIVAT DELAY
0.0s
___________________
___________________
7 SP C3 OF=0[%]]
C3 DEACTIV LEVEL
+0[%]
___________________
___________________
8 T C3 OF=0.0s
C3 DEACTIV DELAY
0.0s
___________________
___________________
9 SEL FUNT C3=00
00
___________________
___________________
G10: Limits
1 MIN1 SP=+0%
SPEED MIN LIMIT1
0%
___________________
___________________
2 MAX1 SP=+100%
SPEED MAX LIMIT1
+100%
___________________
___________________