EasyManua.ls Logo

Power Electronics SD700 Series - G14: Multi-references; G15: Inch Speeds; G20: Communication Buses - S20.2: PROFIBUS; G20: Communication Buses - S20.3: CANOPEN

Power Electronics SD700 Series
105 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SD700
CONFIGURATION REGISTER
97
PARAMETERS
FACTORY SETTINGS
SETTING 1
SETTING 2
3 DC VOLTS=0.0%
DC BR VOLT LEVEL
0.0%
___________________
___________________
4 I HEATING=OFF
Idc HEATING
OFF
___________________
___________________
5 DYN BRAK=N
N
___________________
___________________
G18: Encoder
0 ENCODER = N
N
___________________
___________________
1 PULSES = 1024
1024
___________________
___________________
2 TYPE = DIFF
DIFF
___________________
___________________
3 ENCOD FILTER = N
N
___________________
___________________
G19: Fine Tuning S19.1: IGBT Control
1 TYPE CRTL=V/Hz
V / Hz
___________________
___________________
2 VECTOR CTR = PMC
PMC
___________________
___________________
3 PMC = OL SP
OL SP
___________________
___________________
4 AVC = CL SP
CL SP
___________________
___________________
5 FRQ=4000Hz
MODULAT FREQUENC
4000
___________________
___________________
6 PEWAVE=Y
Y
___________________
___________________
8 Autotune=N
N
___________________
___________________
9 OVERMODULATIO=N
N
___________________
___________________
G19: Fine Tuning S19.2: MTR Load
1 MIN FLUX = 100%
MINIMUM FLUX
100%
___________________
___________________
3 V BOOST = 0.0%
BOOST VOLTAGE
0.0%
___________________
___________________
4 SLIP COMPENS=N
N
___________________
___________________
5 DAMP.gain=0.0%
0.0%
___________________
___________________
7 I SLIP=2.0%
I SLIP COMPENSAT
2.0%
___________________
___________________
9 STR FRQ = 0.0%
START FREQUENCY
0.0%
___________________
___________________
11 DAMP.ref=3%
DAMPINGreferec
3%
___________________
___________________
13 CTR Vbus=800
REGEN BUS VOLT
800
___________________
___________________
G19: Fine Tuning S19.3: MTR Model
1 R STATOR=0.9%
STATOR RESISTOR
0.9%
___________________
___________________
2 R. RTR = 0%
0.0%
___________________
___________________
3 Lm = 40%
40%
___________________
___________________
4 L.I = 0%
0.0%
___________________
___________________
5 FL WEAK = 90%
90%
___________________
___________________
G19: Fine Tuning S19.4: Control PID
1 Kp Sp = 95%
95%
___________________
___________________
2 Ki Sp = 95%
95%
___________________
___________________

Table of Contents