Chapter 4: Technology Background
87
RAID 6
A RAID 6 Source logical drive can migrate to the following Target logical drives:
See “Migrating a Logical Drive” on page 65.
RAID 10
A RAID 10 Source logical drive can migrate to the following Target logical drives:
When you migrate RAID 10 logical drive, it becomes RAID 1E by default.
If you want a RAID 10 logical drive, there must be an even number of physical
drives and you must specify RAID 10 for the target logical drive.
See “Migrating a Logical Drive” on page 65.
Target Requirements
RAID 6 Add physical drives. Maximum of 4 (R4) or 6 (R6).
Target Requirements
RAID 0 None.
RAID 1E None.
RAID 5 3 physical drives minimum, maximum of 4 (R4) or 6 (R6).
RAID 10 must have less than 4 (R4) or 6 (R6) physical drives.
RAID 6 4 physical drives minimum, maximum of 4 (R4) or 6 (R6).
The RAID 10 logical drive must have less than 4 (R4) or 6
(R6) physical drives.
If existing physical drives have no unused space, add 1 or
more physical drives.
RAID 10 Add physical drives in multiples of two.
Even number of physical drives.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Promise Technology Pegasus R6 and is the answer not in the manual?

Promise Technology Pegasus R6 Specifications

General IconGeneral
BrandPromise Technology
ModelPegasus R6
CategoryStorage
LanguageEnglish

Related product manuals