882 Video Test Instrument User Guide (Rev A.35) 3
• Self-calibrating–Analog video outputs are automatically adjusted against an internal
precision reference. This assures video levels that are precise and reliable. Signal
levels are auto-adjusted individually.
• Probe–Trigger a scope or inspection camera using the probe signal. Position a pulse
anywhere in the frame.
• PC Card–Clone one 882 to another using a standard CompactFlash card.
• Auxiliary Channel Analyzer (ACA) –The ACA enables you to monitor DDC, HDCP, CEC
and EDID transactions for HDMI and HDCP, Link Layer and EDID transactions over the
DisplayPort auxiliary channels.
• IEEE-488-GPIB (IEEE-488) interface. interface.
• RS-232-Industry standard serial interface.
882E Optional Features
The following are the optional features available with the 882E. For the 882E one of the
two following options must be selected:
• HDMI 1.3 Transmitter:
• Advanced E-EDID parsing
• Deep Color at 24/30/36-bit/pixel 4:4:4 RGB / YCbCr
• 16/20/24-bit/pixel 4:2:2 YCbCr
• High-level Active Format Description (AFD) controls
•AFD test suite
• Pixel repetition test suite
• Automatic and manual InfoFrame setup
• Compressed Dolby Digital formats (Plus & TrueHD)
• Internal sine wave 882 (LPCM), and external SPDIF audio input
• 32, 44.1, 48, 88.2, 176.4 and 192kHz audio sampling rates
• Generates all EIA/CEA-861D formats below 165 MHz, with all possible variations
• Complete letterbox and scope coverage
• 4:2:2 color sub-sampling at 8, 10, and 12-bits per component
• Hot-plug format list
• Includes DVI-D (M) to HDMI (M) cable and HDMI-HDMI cable.
• HDMI Analyzer available with HDMI Tx on 882E only
• Supports full single-link HDMI 1.3 (with deep color) and DVI analyzer up to
(150MHz) in same instrument.