372 Appendix A Command Reference
HPPW
Hot Plug Pulse Width
Description: The Hot Plug Pulse Width command is used to set the assertion pulse width of the
analyzer’s hot plug pulse.
Command syntax HPPW value
value (milliseconds) in the range of 100 to 4000
Query syntax HPPW?
Query response value
Other required
commands
There are no other commands required.
Related commands There are no other related commands.
Example
HPPW 175 // sets the hot plug assertion pulse width to 175ms
HPPW? // queries the current value for the hot plug pulse assertion