882 Video Test Instrument User Guide (Rev A.35) 379
HSPW
Horizontal Sync Pulse Width
Class Format parameter setting - Synchronization
Description Establishes the width of the horizontal sync pulse. The HSPW? query returns the current
setting of HSPW.
Command syntax HSPW pixels
pixels
min = 1
max = HTOT - HRES - HSPD
Query syntax HSPW?
Query response pixels
Other required
commands
The FMTU command instructs the generator to use the new settings. The ALLU command
updates the hardware to the new settings and redraws the test image.
Example
HSPW 32 // Set pulse width to 32 pixels in buffer
FMTU // Update hardware to current buffer contents