882 Video Test Instrument User Guide (Rev A.35) 437
LSGX:PLAT
LipSync Generator Data Stream Order
Class LipSync Generator/Analyzer
Description Determines which data stream (audio or video) is transferred (sent) first for lipsync test
image.
Command syntax LSGX:PLAT boolean
boolean
0 = video is transferred first (indicating that video takes longer to process–audio is
delayed).
1 = audio is transferred first (indicating that audio takes longer to process–video is
delayed).
Query syntax LSGX:PLAT?
Query response 0 or 1
Example
LSGX:PLAT 1 // Audio is sent first for lipsync test image
LSGX:TLAT 0.5 // Latency between audio and video in lipsync test image