882 Video Test Instrument User Guide (Rev A.35) 439
LSPG
Line Sync Pulse Gate
Class Format parameter settings
Description Enables and disables the digital horizontal sync output. The LSPG? query returns the
current LSPG mode.
Command syntax LSPG mode
mode integer
0 = OFF
1 = ON
Query syntax LSPG?
Query response 0 or 1
Other required
commands
The FMTU command instructs the generator to use the new settings. The ALLU command
updates the hardware to the new settings and redraws the test image.
Example
LSPG 1 // Enable Line Sync
FMTU // Update hardware to new settings