EasyManua.ls Logo

Quantum Data 881 - Page 819

Quantum Data 881
1144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
882 Video Test Instrument User Guide (Rev A.35) 441
MODE
communications MODE
Class System parameter settings
Description Sets the serial port communications parameters of a stand-alone model generator. The
changes take effect as soon as the command is entered. The factory default settings are
baud, no parity, 8 data bits, no stop bits, no handshake (handshake), and no protocol.
Command syntax MODE baud parity data stop handshake protocol
baud rate
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, or 115200 bits/sec
parity
N = None, E = Even or O = Odd
data
number of data bits: 7 or 8
stop
number of stop bits: 1 or 2
handshake
N = None
H = Hardware (CTS/RTS)
protocol
N = None
Y=Y-Modem
Example
MODE 9600 N 8 1 H N // Set a stand alone generator to
// communicate at 9600 Baud, No parity, 8 data bits,
// 1 stop bit, RTS//CTS handshaking and No protocol
or
MODE 2400 // Change only the baud rate

Table of Contents

Related product manuals