464 Appendix A Command Reference
OUTG
OUTputs Gate
Class System parameter settings
Description Gates all video and sync outputs of the generator ON and OFF. Gating the outputs OFF
forces all outputs to be turned off. Gating the outputs ON turns on all outputs whose
individual gating settings are turned ON. The OUTG? query returns the current status of
the outputs of the generator.
Command syntax OUTG mode
mode
0 = OFF
1 = ON
Query syntax OUTG?
Query response mode
Example
OUTG 0
ALLU