882 Video Test Instrument User Guide (Rev A.35) 469
PDAX:FRMS
Pixel Data Analyzer for number of FRaMes
Class Signal analyzer - Pixel data
Description Determines how many frames to analyze.
Command syntax PDAX:FRMS frames
frames
number of frames analyzed in a range from 1 to 1,000,000
Query syntax PDAX:FRMS?
Query response frames
Example
PDAX:FRMS 100 //sets the number of frames to analyze in the pixel
data analysis test to 100
PDAX:MXER 1000 //sets the maximum number of errors to record in pixel
data analysis test to 1000
PDAX:RPTG 1 //enables the generation of reports for the ppixel
data analysis test
PDAX:REFG 1 //enables auto reference capturing for the pixel
data analysis test
PDAX:CAPF //captures a frame of pixel data for the pixel
data analysis test
PDAU: //runs the pixel data analysis test
Related commands PDAX:MXER, PDAX:RPTG, PDAX:REFG, PDAX:CAPF, PDAU