882 Video Test Instrument User Guide (Rev A.35) 481
PDAX:VIEW
Pixel Data Analyzer View Data
Class Signal analyzer - Pixel data
Description Output captured image during pixel data analysis test to HDMI output ports.
Command syntax PDAX:VIEW
Example
PDAX:FRMS 100 //sets the number of frames to analyze in the pixel
data analysis test to 100
PDAX:MXER 1000 //sets the maximum number of errors to record in pixel
data analysis test to 1000
PDAX:RPTG 1 //enables the generation of reports for the ppixel
data analysis test
PDAX:REFG 0 //enables auto reference capturing for the pixel
data analysis test
PDAX:CAPF //captures a frame of pixel data for the pixel
data analysis test
PDAU: //runs the pixel data analysis test
PDAX:VIEW //output captured image from HDMI OUT ports
Related commands PDAX:MXER, PDAX:RPTG, PDAX:REFG, PDAX:FRMS, PDAU