882 Video Test Instrument User Guide (Rev A.35) 505
RFLD
Repeat FieLD
Class Format parameter setting - Video resolution
Description Determines if identical video information is output for each field of an interlaced (SCAN =
2) format. The RFLD? query returns the current setting of RFLD.
Command syntax RFLD mode
mode
0 = disabled
1 = enabled
Query syntax RFLD?
Query response 0 or 1
Other required
commands
FMTU or ALLU
Example
SCAN 2 // Set Interlaced scanning
RFLD 1 // Enable repeat field buffer
FMTU // Update hardware with format data