882 Video Test Instrument User Guide (Rev A.35) 555
TOGG
TOGGle Hot Plug (enable/disable)
Class System
Description Enables or disables reading EDID from sink to set the Source list to hot plug formats.
When enabled, only EDID formats will be shown in the Source list.
Command syntax TOGG mode
mode
1
Enable reading of EDID from sink. This is equivalent to pressing the Sink->Options
key sequence and enabling EDID formats.
0
Disable read of EDID from sink. This is equivalent to pressing the Sink->Options key
sequence and disabling EDID formats.
Query syntax TOGG?
Query response mode
Example
TOGG 0 // disables EDID formats
TOGG 1 // enables EDID formats