196
SCC
Edition 10-2008a
SCC Service Reference
SCC key c
Function key a
Prog key b
Settings
Starttime
CleanJet
1
2
3
4
SelfCooking Center
http://service.rational-ag.de
(since SW SCC 02_xx_xx to 03_xx_ (since SW SCC 04_xx_xx)
Settings
Starttime
+
r
10:2
englis
am/p
24
h:
m:
IP
10/22/06
22.10.06
Mo
descale
Service Info
Settings
Setting of language
reset to factory setting
Setting CleanJet request (only activ
when frame shows in red)
Descaling program: automatic process
empty steam generator (Door must
be open!)
Display of scale level inside steam
generator
Display of software version, Serial
number
erase all customer programs
„Program lock“ Password;12345;
TTREU
setting buzzer (sound-duration)
Copy customer program to stick
Reload customer programs from stick
to unit
Erase customer programs
Download of HACCP-Data
Software updates (Icon only shows
when unit detects valid software on
the usb stick;
Download of service data to stick.
Prog
Software
update
update
P, H, I 05, S05
Chef Line
h:m
m:s
Prog
Prog
SelfCooking Center
°
°
Show Mode - switch off or on
ON press function key „a“ followed by program key „b“ and
SCC key „c“ for 10 seconds until -
acoustic signal - Beep and door handle in icon function
key „a“ shows in red
OFF press function key „a“ followed by program key „b“ and
SCC key „c“ for 10 seconds until -
acoustic signal - Beep
and door handle in icon function key „a“ shows in blue
Abort CleanJet
switch unit off and on again
Abort de-scaling program
before lling de-scaling liquid - use „BACK“ arrow
after lling de-scaler into steam generator
- switch unit off and on again
- press ABORT key - remaining time will be adjusted automati-
cally
- switch unit off and on again
- press ABORT key - time will be adjusted automatically 2x
- use steam mode for 15 min. and rinse interior cabinet
Enter Service level
set dip switch „1“ on pcb to ON position
Diagnostic
RunningTimes
Function Test
Basic Settings
1
2
on