EasyManua.ls Logo

Rational SCC Series

Rational SCC Series
200 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
53
SCC
Edition 10-2008a
Sequence Cleanjet+Care Process: 2. step - Care Steam generator and cabinet; example: SCC 61, Index G
Prepare care solution Care process Neutralising steam generator and cabinet
Solenoid Y4 Care
Care Tabs are disolved in several setps 1
Drain care solution from container 0
Care Pump M12
Pump care solution into steam generator 1
Pump remaining care solution from container 0
Drain valve M7 1
0
Solenoid Filling Y1
Topping up of care solution above level electrode 1
Fill steam generator 0
SC-Pump M4 , Partial separation of care solution
from steam generator to quenching box 1
Rinse steam generator 0
Level electrode S2 1
0
Solenoid Moistening Y3
Topping up of care solution for cabinet 1
0
Steam heating element to 80° water temperature 1
Neutralising of cabinet and steam generator 0
Cleanjet Pump M6 1
Pumping of care solution through cabinet 0
Service 110Service 120

Table of Contents