53
SCC
Edition 10-2008a
Sequence Cleanjet+Care Process: 2. step - Care Steam generator and cabinet; example: SCC 61, Index G
Prepare care solution Care process Neutralising steam generator and cabinet
Solenoid Y4 Care
Care Tabs are disolved in several setps 1
Drain care solution from container 0
Care Pump M12
Pump care solution into steam generator 1
Pump remaining care solution from container 0
Drain valve M7 1
0
Solenoid Filling Y1
Topping up of care solution above level electrode 1
Fill steam generator 0
SC-Pump M4 , Partial separation of care solution
from steam generator to quenching box 1
Rinse steam generator 0
Level electrode S2 1
0
Solenoid Moistening Y3
Topping up of care solution for cabinet 1
0
Steam heating element to 80° water temperature 1
Neutralising of cabinet and steam generator 0
Cleanjet Pump M6 1
Pumping of care solution through cabinet 0
Service 110Service 120