SCC - Sequence of events
Low temperature steam: Temperature range 30-97°C (85-207°F)
Function step Responsible sensor
1 Select Wet heat (Temp 30-97°C (85-207°F))
2 Select time or core temperature
3 Close cabinet door Reed switch S3
4 Check water level inside steam generator Level electrode S2 inside Steam Gen
5 Time based preheating of steam generator,
if B5 is below 85°C (185°F)
Thermocouple B5 inside Steam Gen.
6 Timer starts after successful preheating Logic on PCB
7 Steam supply until set temperature inside cabinet
is reached
Cabinet sensor B1
8 Adding of Hot Air from 93°C (200°F) possible
(only 50%)
Cabinet sensor B1
9 Quenching (set to 70°C/158°F) Thermocouple B2
Note: Steam heating only active when humidity ap (S4) is in closed position!
Below 98°C fan at lowest speed when no energy required for longer than 2 minutes.
Additional functions possible: 4 Fan speeds (Standard = Level 3), pulsed fan wheel, ½ Energy,